PRODUCT DETAILS
SureStart compact low voltage disconnect switch
No more dead batteries! 12 or 24V, 125A at 60 ºC, 100A at 85 ºC. Unit is auto-ranging: identifi es whether system is 12V or 24V and automatically establishes thresholds. Automatically disconnects and reconnects loads based on battery condition; no operator action is required to protect the batteries. Prolongs battery life by preventing damage due to excessive discharge. Eliminates the need for both separate timer or voltage sensing delay relay devices and high current relay or solenoid, and simplifi es wiring and installation. When battery voltage falls below programmed voltage setting for 2 minutes non-critical loads are automatically disconnected. Waterproof and dustproof to IP67. Sealed connector makes it ideal for harsh environments. Programmable timer feature automatically disconnects loads after key off, regardless of battery condition.
• Operating Voltage: 9V min, 12V typical, 16V max if used with 12V DC systems
• Disconnect Voltage: 12.05V min, 12.1V typical, 12.15V max
• When voltage drops below 12.1V, system activates the alarm for one minute and then disconnects
loads
• Load Current: 100A at 85 °C, 125A at 60 °C
• Overcurrent Protection: 150A. System will disconnect load and sound alarm after 5 seconds of
excessive current
• Key-Off timer: 5 minutes minimum, 15 minutes typical
|